10+ Years Exp.

Safe, Convenient Power Where You Need It

Extra outlets, USB ports, and overload protection—safe, modern power exactly where needed.

Tidy Up, Power Up

Tired of juggling power boards and tangled cords? Overloaded outlets are not just messy—they’re a fire risk.

Whether you’re renovating or just sick of unplugging the toaster to charge your phone, McGuire’s licensed sparkies deliver safe, compliant power point installations that meet AS/NZS 3000 standards and make everyday life easier.

What We Install?

New double & quad GPOs

(General Purpose Outlets)

USB A/C charging outlets

Fast charge your phone, tablet or watch

Appliance isolators

For dishwashers, ovens, pool pumps & hot water

Weatherproof outdoor outlets

IP56 rated for patio, BBQ & garden zones

Relocation or extension

Move existing outlets to suit furniture or layout

Child-safe & slimline sockets

For peace of mind and style

All outlets comply with SAA approvals and carry RCM markings.

Why Upgrade?

Eliminate fire risks, future-proof with USB-C outlets, reduce hazards, ensure compliance, and boost home value with modern, smart power solutions.

Compliance & Safety

Every installation is:

Our Process

We assess your space, help you choose finishes, install neatly, test for safety, and clean thoroughly—delivering a seamless, professional power point installation from start to finish.

1

On-Site Assessment

We locate studs, verify wall cavity space, and check circuit availability

2

Quote & Product Choice

Choose between white, brushed metal or designer finishes

3

Install

Dust-controlled drilling, fitted level and flush

4

Test & Certify

Confirm polarity, insulation resistance & circuit load

5

Tidy Up

We vacuum up brick dust and leave the area spotless

Power Point Installation FAQ

Power point installations must be done by licensed electricians to ensure legal compliance, safety, proper circuit protection, and compatibility with wall types and modern devices.

Yes—always. In WA, only licensed electricians can legally install, relocate or alter power points. This is mandated by Electricity (Licensing) Regulations 1991 and AS/NZS 3000. DIY is illegal and dangerous—insurance won’t cover you in the event of a fire.

Usually yes—but it depends on access and wall type. For brick walls, we use wall chasing and conduits or surface-mount ducting. For stud walls, we feed cables inside the cavity. We’ll check for clearance, structural framing and nearby plumbing or gas lines before installation.

  • Double GPO: Standard two-socket outlet
  • Quad GPO: Four sockets in a single plate – perfect behind TVs, desks or kitchen benches

Both types must comply with AS/NZS 3112, and McGuire’s only installs SAA-certified fittings.

Yes, if installed correctly and from trusted brands.

We use outlets with:

  • Short-circuit protection
  • Overload protection
  • Smart charge detection
  • Certified to AS/NZS 60950 or AS/NZS IEC 62368

We recommend USB-A + USB-C combos for future-proof charging.

This depends on the circuit breaker rating and expected load.

Typically:

  • 10A circuit: up to 8 double outlets (light usage)
  • 20A circuit: more outlets or appliance-specific use

We always calculate the total demand (VA) and balance circuits to prevent overload.

Yes mandatory. Under AS/NZS 3000 Clause 2.6.3, every new or altered socket outlet must be protected by a residual current device (RCD). If your switchboard doesn’t have one, we’ll advise on RCD retrofitting as part of the quote.

Yes—we use IP56-rated GPOs suitable for alfresco, garage or garden use.
We install:

  • Proper mounting blocks
  • Silicone sealant
  • Conduit protection
  • Compliant RCD protection for all external circuits

This keeps you safe from rain, dust, and corrosion

Per AS/NZS 3000, GPOs must be:

  • At least 150mm above benches
  • 600mm horizontally from sinks or cooktops (Zone 2 safety clearance)
  • NOT directly above a cooktop or sink basin

We ensure your layout is fully compliant and practical.

Can you install weatherproof outdoor outlets?Yes, if the fitting is designed for continuous use and is IP-rated.

  • IP65 or higher recommended for garden and wall lighting
  • Low-wattage (3–7W) LEDs are ideal for dusk-to-dawn operation
  • Optional motion sensors or timers help reduce usage

All fittings we supply are rated for long operation and backed by AS/NZS 60598 compliance.

Usually 30–60 minutes per outlet, depending on wall type and access.
A full quote will include:

  • Travel
  • Labour
  • Parts
  • Compliance testing

We offer same-day or next-day service, and you’ll receive a digital Certificate of Electrical Safety post-install.

Book Your Free Power Point Installation

Need outlets where you actually use your devices?
Book a same‑day install  McGuire’s services all Perth metro suburbs.